Notification Settings card

This commit is contained in:
headlesdev
2025-05-26 11:30:19 +02:00
parent d045aad2dd
commit 338c1922d0
14 changed files with 121 additions and 17 deletions

File diff suppressed because one or more lines are too long

View File

@@ -198,6 +198,7 @@ exports.Prisma.ApplicationMonitoringScalarFieldEnum = {
exports.Prisma.ServerMonitoringNotificationScalarFieldEnum = {
id: 'id',
enabled: 'enabled',
statusChange: 'statusChange',
cpuLimit: 'cpuLimit',
gpuLimit: 'gpuLimit',
@@ -219,6 +220,7 @@ exports.Prisma.ServerMonitoringNotificationScalarFieldEnum = {
exports.Prisma.ApplicationMonitoringNotificationScalarFieldEnum = {
id: 'id',
enabled: 'enabled',
statusChange: 'statusChange',
latencyLimit: 'latencyLimit',
notificationTextStatus: 'notificationTextStatus',

View File

@@ -9985,6 +9985,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationMinAggregateOutputType = {
id: number | null
enabled: boolean | null
statusChange: boolean | null
cpuLimit: number | null
gpuLimit: number | null
@@ -10006,6 +10007,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationMaxAggregateOutputType = {
id: number | null
enabled: boolean | null
statusChange: boolean | null
cpuLimit: number | null
gpuLimit: number | null
@@ -10027,6 +10029,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationCountAggregateOutputType = {
id: number
enabled: number
statusChange: number
cpuLimit: number
gpuLimit: number
@@ -10068,6 +10071,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationMinAggregateInputType = {
id?: true
enabled?: true
statusChange?: true
cpuLimit?: true
gpuLimit?: true
@@ -10089,6 +10093,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationMaxAggregateInputType = {
id?: true
enabled?: true
statusChange?: true
cpuLimit?: true
gpuLimit?: true
@@ -10110,6 +10115,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationCountAggregateInputType = {
id?: true
enabled?: true
statusChange?: true
cpuLimit?: true
gpuLimit?: true
@@ -10218,6 +10224,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationGroupByOutputType = {
id: number
enabled: boolean
statusChange: boolean
cpuLimit: number
gpuLimit: number
@@ -10258,6 +10265,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationSelect<ExtArgs extends $Extensions.InternalArgs = $Extensions.DefaultArgs> = $Extensions.GetSelect<{
id?: boolean
enabled?: boolean
statusChange?: boolean
cpuLimit?: boolean
gpuLimit?: boolean
@@ -10279,6 +10287,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationSelectCreateManyAndReturn<ExtArgs extends $Extensions.InternalArgs = $Extensions.DefaultArgs> = $Extensions.GetSelect<{
id?: boolean
enabled?: boolean
statusChange?: boolean
cpuLimit?: boolean
gpuLimit?: boolean
@@ -10300,6 +10309,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationSelectUpdateManyAndReturn<ExtArgs extends $Extensions.InternalArgs = $Extensions.DefaultArgs> = $Extensions.GetSelect<{
id?: boolean
enabled?: boolean
statusChange?: boolean
cpuLimit?: boolean
gpuLimit?: boolean
@@ -10321,6 +10331,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationSelectScalar = {
id?: boolean
enabled?: boolean
statusChange?: boolean
cpuLimit?: boolean
gpuLimit?: boolean
@@ -10340,13 +10351,14 @@ export namespace Prisma {
notificationTemperature?: boolean
}
export type ServerMonitoringNotificationOmit<ExtArgs extends $Extensions.InternalArgs = $Extensions.DefaultArgs> = $Extensions.GetOmit<"id" | "statusChange" | "cpuLimit" | "gpuLimit" | "memoryLimit" | "diskLimit" | "temperatureLimit" | "notificationTextStatus" | "notificationTextCpu" | "notificationTextGpu" | "notificationTextMemory" | "notificationTextDisk" | "notificationTextTemperature" | "notificationCpu" | "notificationGpu" | "notificationMemory" | "notificationDisk" | "notificationTemperature", ExtArgs["result"]["serverMonitoringNotification"]>
export type ServerMonitoringNotificationOmit<ExtArgs extends $Extensions.InternalArgs = $Extensions.DefaultArgs> = $Extensions.GetOmit<"id" | "enabled" | "statusChange" | "cpuLimit" | "gpuLimit" | "memoryLimit" | "diskLimit" | "temperatureLimit" | "notificationTextStatus" | "notificationTextCpu" | "notificationTextGpu" | "notificationTextMemory" | "notificationTextDisk" | "notificationTextTemperature" | "notificationCpu" | "notificationGpu" | "notificationMemory" | "notificationDisk" | "notificationTemperature", ExtArgs["result"]["serverMonitoringNotification"]>
export type $ServerMonitoringNotificationPayload<ExtArgs extends $Extensions.InternalArgs = $Extensions.DefaultArgs> = {
name: "ServerMonitoringNotification"
objects: {}
scalars: $Extensions.GetPayloadResult<{
id: number
enabled: boolean
statusChange: boolean
cpuLimit: number
gpuLimit: number
@@ -10788,6 +10800,7 @@ export namespace Prisma {
*/
interface ServerMonitoringNotificationFieldRefs {
readonly id: FieldRef<"ServerMonitoringNotification", 'Int'>
readonly enabled: FieldRef<"ServerMonitoringNotification", 'Boolean'>
readonly statusChange: FieldRef<"ServerMonitoringNotification", 'Boolean'>
readonly cpuLimit: FieldRef<"ServerMonitoringNotification", 'Float'>
readonly gpuLimit: FieldRef<"ServerMonitoringNotification", 'Float'>
@@ -11195,6 +11208,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationMinAggregateOutputType = {
id: number | null
enabled: boolean | null
statusChange: boolean | null
latencyLimit: number | null
notificationTextStatus: string | null
@@ -11204,6 +11218,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationMaxAggregateOutputType = {
id: number | null
enabled: boolean | null
statusChange: boolean | null
latencyLimit: number | null
notificationTextStatus: string | null
@@ -11213,6 +11228,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationCountAggregateOutputType = {
id: number
enabled: number
statusChange: number
latencyLimit: number
notificationTextStatus: number
@@ -11234,6 +11250,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationMinAggregateInputType = {
id?: true
enabled?: true
statusChange?: true
latencyLimit?: true
notificationTextStatus?: true
@@ -11243,6 +11260,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationMaxAggregateInputType = {
id?: true
enabled?: true
statusChange?: true
latencyLimit?: true
notificationTextStatus?: true
@@ -11252,6 +11270,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationCountAggregateInputType = {
id?: true
enabled?: true
statusChange?: true
latencyLimit?: true
notificationTextStatus?: true
@@ -11348,6 +11367,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationGroupByOutputType = {
id: number
enabled: boolean
statusChange: boolean
latencyLimit: number
notificationTextStatus: string
@@ -11376,6 +11396,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationSelect<ExtArgs extends $Extensions.InternalArgs = $Extensions.DefaultArgs> = $Extensions.GetSelect<{
id?: boolean
enabled?: boolean
statusChange?: boolean
latencyLimit?: boolean
notificationTextStatus?: boolean
@@ -11385,6 +11406,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationSelectCreateManyAndReturn<ExtArgs extends $Extensions.InternalArgs = $Extensions.DefaultArgs> = $Extensions.GetSelect<{
id?: boolean
enabled?: boolean
statusChange?: boolean
latencyLimit?: boolean
notificationTextStatus?: boolean
@@ -11394,6 +11416,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationSelectUpdateManyAndReturn<ExtArgs extends $Extensions.InternalArgs = $Extensions.DefaultArgs> = $Extensions.GetSelect<{
id?: boolean
enabled?: boolean
statusChange?: boolean
latencyLimit?: boolean
notificationTextStatus?: boolean
@@ -11403,6 +11426,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationSelectScalar = {
id?: boolean
enabled?: boolean
statusChange?: boolean
latencyLimit?: boolean
notificationTextStatus?: boolean
@@ -11410,13 +11434,14 @@ export namespace Prisma {
notificationLatency?: boolean
}
export type ApplicationMonitoringNotificationOmit<ExtArgs extends $Extensions.InternalArgs = $Extensions.DefaultArgs> = $Extensions.GetOmit<"id" | "statusChange" | "latencyLimit" | "notificationTextStatus" | "notificationTextLatency" | "notificationLatency", ExtArgs["result"]["applicationMonitoringNotification"]>
export type ApplicationMonitoringNotificationOmit<ExtArgs extends $Extensions.InternalArgs = $Extensions.DefaultArgs> = $Extensions.GetOmit<"id" | "enabled" | "statusChange" | "latencyLimit" | "notificationTextStatus" | "notificationTextLatency" | "notificationLatency", ExtArgs["result"]["applicationMonitoringNotification"]>
export type $ApplicationMonitoringNotificationPayload<ExtArgs extends $Extensions.InternalArgs = $Extensions.DefaultArgs> = {
name: "ApplicationMonitoringNotification"
objects: {}
scalars: $Extensions.GetPayloadResult<{
id: number
enabled: boolean
statusChange: boolean
latencyLimit: number
notificationTextStatus: string
@@ -11846,6 +11871,7 @@ export namespace Prisma {
*/
interface ApplicationMonitoringNotificationFieldRefs {
readonly id: FieldRef<"ApplicationMonitoringNotification", 'Int'>
readonly enabled: FieldRef<"ApplicationMonitoringNotification", 'Boolean'>
readonly statusChange: FieldRef<"ApplicationMonitoringNotification", 'Boolean'>
readonly latencyLimit: FieldRef<"ApplicationMonitoringNotification", 'Float'>
readonly notificationTextStatus: FieldRef<"ApplicationMonitoringNotification", 'String'>
@@ -14500,6 +14526,7 @@ export namespace Prisma {
export const ServerMonitoringNotificationScalarFieldEnum: {
id: 'id',
enabled: 'enabled',
statusChange: 'statusChange',
cpuLimit: 'cpuLimit',
gpuLimit: 'gpuLimit',
@@ -14524,6 +14551,7 @@ export namespace Prisma {
export const ApplicationMonitoringNotificationScalarFieldEnum: {
id: 'id',
enabled: 'enabled',
statusChange: 'statusChange',
latencyLimit: 'latencyLimit',
notificationTextStatus: 'notificationTextStatus',
@@ -15204,6 +15232,7 @@ export namespace Prisma {
OR?: ServerMonitoringNotificationWhereInput[]
NOT?: ServerMonitoringNotificationWhereInput | ServerMonitoringNotificationWhereInput[]
id?: IntFilter<"ServerMonitoringNotification"> | number
enabled?: BoolFilter<"ServerMonitoringNotification"> | boolean
statusChange?: BoolFilter<"ServerMonitoringNotification"> | boolean
cpuLimit?: FloatFilter<"ServerMonitoringNotification"> | number
gpuLimit?: FloatFilter<"ServerMonitoringNotification"> | number
@@ -15225,6 +15254,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationOrderByWithRelationInput = {
id?: SortOrder
enabled?: SortOrder
statusChange?: SortOrder
cpuLimit?: SortOrder
gpuLimit?: SortOrder
@@ -15249,6 +15279,7 @@ export namespace Prisma {
AND?: ServerMonitoringNotificationWhereInput | ServerMonitoringNotificationWhereInput[]
OR?: ServerMonitoringNotificationWhereInput[]
NOT?: ServerMonitoringNotificationWhereInput | ServerMonitoringNotificationWhereInput[]
enabled?: BoolFilter<"ServerMonitoringNotification"> | boolean
statusChange?: BoolFilter<"ServerMonitoringNotification"> | boolean
cpuLimit?: FloatFilter<"ServerMonitoringNotification"> | number
gpuLimit?: FloatFilter<"ServerMonitoringNotification"> | number
@@ -15270,6 +15301,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationOrderByWithAggregationInput = {
id?: SortOrder
enabled?: SortOrder
statusChange?: SortOrder
cpuLimit?: SortOrder
gpuLimit?: SortOrder
@@ -15299,6 +15331,7 @@ export namespace Prisma {
OR?: ServerMonitoringNotificationScalarWhereWithAggregatesInput[]
NOT?: ServerMonitoringNotificationScalarWhereWithAggregatesInput | ServerMonitoringNotificationScalarWhereWithAggregatesInput[]
id?: IntWithAggregatesFilter<"ServerMonitoringNotification"> | number
enabled?: BoolWithAggregatesFilter<"ServerMonitoringNotification"> | boolean
statusChange?: BoolWithAggregatesFilter<"ServerMonitoringNotification"> | boolean
cpuLimit?: FloatWithAggregatesFilter<"ServerMonitoringNotification"> | number
gpuLimit?: FloatWithAggregatesFilter<"ServerMonitoringNotification"> | number
@@ -15323,6 +15356,7 @@ export namespace Prisma {
OR?: ApplicationMonitoringNotificationWhereInput[]
NOT?: ApplicationMonitoringNotificationWhereInput | ApplicationMonitoringNotificationWhereInput[]
id?: IntFilter<"ApplicationMonitoringNotification"> | number
enabled?: BoolFilter<"ApplicationMonitoringNotification"> | boolean
statusChange?: BoolFilter<"ApplicationMonitoringNotification"> | boolean
latencyLimit?: FloatFilter<"ApplicationMonitoringNotification"> | number
notificationTextStatus?: StringFilter<"ApplicationMonitoringNotification"> | string
@@ -15332,6 +15366,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationOrderByWithRelationInput = {
id?: SortOrder
enabled?: SortOrder
statusChange?: SortOrder
latencyLimit?: SortOrder
notificationTextStatus?: SortOrder
@@ -15344,6 +15379,7 @@ export namespace Prisma {
AND?: ApplicationMonitoringNotificationWhereInput | ApplicationMonitoringNotificationWhereInput[]
OR?: ApplicationMonitoringNotificationWhereInput[]
NOT?: ApplicationMonitoringNotificationWhereInput | ApplicationMonitoringNotificationWhereInput[]
enabled?: BoolFilter<"ApplicationMonitoringNotification"> | boolean
statusChange?: BoolFilter<"ApplicationMonitoringNotification"> | boolean
latencyLimit?: FloatFilter<"ApplicationMonitoringNotification"> | number
notificationTextStatus?: StringFilter<"ApplicationMonitoringNotification"> | string
@@ -15353,6 +15389,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationOrderByWithAggregationInput = {
id?: SortOrder
enabled?: SortOrder
statusChange?: SortOrder
latencyLimit?: SortOrder
notificationTextStatus?: SortOrder
@@ -15370,6 +15407,7 @@ export namespace Prisma {
OR?: ApplicationMonitoringNotificationScalarWhereWithAggregatesInput[]
NOT?: ApplicationMonitoringNotificationScalarWhereWithAggregatesInput | ApplicationMonitoringNotificationScalarWhereWithAggregatesInput[]
id?: IntWithAggregatesFilter<"ApplicationMonitoringNotification"> | number
enabled?: BoolWithAggregatesFilter<"ApplicationMonitoringNotification"> | boolean
statusChange?: BoolWithAggregatesFilter<"ApplicationMonitoringNotification"> | boolean
latencyLimit?: FloatWithAggregatesFilter<"ApplicationMonitoringNotification"> | number
notificationTextStatus?: StringWithAggregatesFilter<"ApplicationMonitoringNotification"> | string
@@ -16011,6 +16049,7 @@ export namespace Prisma {
}
export type ServerMonitoringNotificationCreateInput = {
enabled?: boolean
statusChange: boolean
cpuLimit: number
gpuLimit: number
@@ -16032,6 +16071,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationUncheckedCreateInput = {
id?: number
enabled?: boolean
statusChange: boolean
cpuLimit: number
gpuLimit: number
@@ -16052,6 +16092,7 @@ export namespace Prisma {
}
export type ServerMonitoringNotificationUpdateInput = {
enabled?: BoolFieldUpdateOperationsInput | boolean
statusChange?: BoolFieldUpdateOperationsInput | boolean
cpuLimit?: FloatFieldUpdateOperationsInput | number
gpuLimit?: FloatFieldUpdateOperationsInput | number
@@ -16073,6 +16114,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationUncheckedUpdateInput = {
id?: IntFieldUpdateOperationsInput | number
enabled?: BoolFieldUpdateOperationsInput | boolean
statusChange?: BoolFieldUpdateOperationsInput | boolean
cpuLimit?: FloatFieldUpdateOperationsInput | number
gpuLimit?: FloatFieldUpdateOperationsInput | number
@@ -16094,6 +16136,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationCreateManyInput = {
id?: number
enabled?: boolean
statusChange: boolean
cpuLimit: number
gpuLimit: number
@@ -16114,6 +16157,7 @@ export namespace Prisma {
}
export type ServerMonitoringNotificationUpdateManyMutationInput = {
enabled?: BoolFieldUpdateOperationsInput | boolean
statusChange?: BoolFieldUpdateOperationsInput | boolean
cpuLimit?: FloatFieldUpdateOperationsInput | number
gpuLimit?: FloatFieldUpdateOperationsInput | number
@@ -16135,6 +16179,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationUncheckedUpdateManyInput = {
id?: IntFieldUpdateOperationsInput | number
enabled?: BoolFieldUpdateOperationsInput | boolean
statusChange?: BoolFieldUpdateOperationsInput | boolean
cpuLimit?: FloatFieldUpdateOperationsInput | number
gpuLimit?: FloatFieldUpdateOperationsInput | number
@@ -16155,6 +16200,7 @@ export namespace Prisma {
}
export type ApplicationMonitoringNotificationCreateInput = {
enabled?: boolean
statusChange: boolean
latencyLimit: number
notificationTextStatus: string
@@ -16164,6 +16210,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationUncheckedCreateInput = {
id?: number
enabled?: boolean
statusChange: boolean
latencyLimit: number
notificationTextStatus: string
@@ -16172,6 +16219,7 @@ export namespace Prisma {
}
export type ApplicationMonitoringNotificationUpdateInput = {
enabled?: BoolFieldUpdateOperationsInput | boolean
statusChange?: BoolFieldUpdateOperationsInput | boolean
latencyLimit?: FloatFieldUpdateOperationsInput | number
notificationTextStatus?: StringFieldUpdateOperationsInput | string
@@ -16181,6 +16229,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationUncheckedUpdateInput = {
id?: IntFieldUpdateOperationsInput | number
enabled?: BoolFieldUpdateOperationsInput | boolean
statusChange?: BoolFieldUpdateOperationsInput | boolean
latencyLimit?: FloatFieldUpdateOperationsInput | number
notificationTextStatus?: StringFieldUpdateOperationsInput | string
@@ -16190,6 +16239,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationCreateManyInput = {
id?: number
enabled?: boolean
statusChange: boolean
latencyLimit: number
notificationTextStatus: string
@@ -16198,6 +16248,7 @@ export namespace Prisma {
}
export type ApplicationMonitoringNotificationUpdateManyMutationInput = {
enabled?: BoolFieldUpdateOperationsInput | boolean
statusChange?: BoolFieldUpdateOperationsInput | boolean
latencyLimit?: FloatFieldUpdateOperationsInput | number
notificationTextStatus?: StringFieldUpdateOperationsInput | string
@@ -16207,6 +16258,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationUncheckedUpdateManyInput = {
id?: IntFieldUpdateOperationsInput | number
enabled?: BoolFieldUpdateOperationsInput | boolean
statusChange?: BoolFieldUpdateOperationsInput | boolean
latencyLimit?: FloatFieldUpdateOperationsInput | number
notificationTextStatus?: StringFieldUpdateOperationsInput | string
@@ -16873,6 +16925,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationCountOrderByAggregateInput = {
id?: SortOrder
enabled?: SortOrder
statusChange?: SortOrder
cpuLimit?: SortOrder
gpuLimit?: SortOrder
@@ -16903,6 +16956,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationMaxOrderByAggregateInput = {
id?: SortOrder
enabled?: SortOrder
statusChange?: SortOrder
cpuLimit?: SortOrder
gpuLimit?: SortOrder
@@ -16924,6 +16978,7 @@ export namespace Prisma {
export type ServerMonitoringNotificationMinOrderByAggregateInput = {
id?: SortOrder
enabled?: SortOrder
statusChange?: SortOrder
cpuLimit?: SortOrder
gpuLimit?: SortOrder
@@ -16954,6 +17009,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationCountOrderByAggregateInput = {
id?: SortOrder
enabled?: SortOrder
statusChange?: SortOrder
latencyLimit?: SortOrder
notificationTextStatus?: SortOrder
@@ -16968,6 +17024,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationMaxOrderByAggregateInput = {
id?: SortOrder
enabled?: SortOrder
statusChange?: SortOrder
latencyLimit?: SortOrder
notificationTextStatus?: SortOrder
@@ -16977,6 +17034,7 @@ export namespace Prisma {
export type ApplicationMonitoringNotificationMinOrderByAggregateInput = {
id?: SortOrder
enabled?: SortOrder
statusChange?: SortOrder
latencyLimit?: SortOrder
notificationTextStatus?: SortOrder

File diff suppressed because one or more lines are too long

View File

@@ -1,5 +1,5 @@
{
"name": "prisma-client-52e4968f48cbb793854bc8e714c5b303338856d538203e7dea8fac926820a4d3",
"name": "prisma-client-64aff5cfd2cd1523f0bb1f03af9aeb274dcb23e50868aec227bc1494fa5a7d27",
"main": "index.js",
"types": "index.d.ts",
"browser": "index-browser.js",

View File

@@ -120,6 +120,7 @@ model ApplicationMonitoring {
model ServerMonitoringNotification {
id Int @id @default(autoincrement())
enabled Boolean @default(false)
statusChange Boolean
cpuLimit Float
gpuLimit Float
@@ -143,6 +144,7 @@ model ServerMonitoringNotification {
model ApplicationMonitoringNotification {
id Int @id @default(autoincrement())
enabled Boolean @default(false)
statusChange Boolean
latencyLimit Float
notificationTextStatus String

View File

@@ -198,6 +198,7 @@ exports.Prisma.ApplicationMonitoringScalarFieldEnum = {
exports.Prisma.ServerMonitoringNotificationScalarFieldEnum = {
id: 'id',
enabled: 'enabled',
statusChange: 'statusChange',
cpuLimit: 'cpuLimit',
gpuLimit: 'gpuLimit',
@@ -219,6 +220,7 @@ exports.Prisma.ServerMonitoringNotificationScalarFieldEnum = {
exports.Prisma.ApplicationMonitoringNotificationScalarFieldEnum = {
id: 'id',
enabled: 'enabled',
statusChange: 'statusChange',
latencyLimit: 'latencyLimit',
notificationTextStatus: 'notificationTextStatus',

View File

@@ -0,0 +1,5 @@
-- AlterTable
ALTER TABLE "application_monitoring_notifications" ADD COLUMN "enabled" BOOLEAN NOT NULL DEFAULT false;
-- AlterTable
ALTER TABLE "server_monitoring_notifications" ADD COLUMN "enabled" BOOLEAN NOT NULL DEFAULT false;

View File

@@ -122,6 +122,7 @@ model ApplicationMonitoring {
model ServerMonitoringNotification {
id Int @id @default(autoincrement())
enabled Boolean @default(false)
statusChange Boolean
cpuLimit Float
gpuLimit Float
@@ -145,6 +146,7 @@ model ServerMonitoringNotification {
model ApplicationMonitoringNotification {
id Int @id @default(autoincrement())
enabled Boolean @default(false)
statusChange Boolean
latencyLimit Float
notificationTextStatus String